Save 20%

Mouse Mannose Binding Lectin 2/MBL-2 ELISA

RayBio® Mouse Mannose Binding Lectin 2/MBL-2 ELISA Kit for Serum, Plasma, and Cell Culture Supernatants.

Old price: $457.00
$365.60
You save: $91.40 (20%)
ELM-MBL2-1
+

Antigen Information

Accession Number:
  • P41317
Gene ID:
  • 17195
Gene Names:
  • MBL2
Protein Name & Synonyms:
Mannose-binding protein C (MBP-C) (Mannan-binding protein) (RA-reactive factor P28A subunit) (RARF/P28A)

Assay Format

Detection Range:
0.055 ng/ml - 12.50 ng/ml
Recommended Dilution (serum & plasma):
4000 fold
Sensitivity:
0.055 ng/ml
Specificity:
This ELISA kit shows no cross-reactivity with the following cytokines tested: Mouse BAFF R, Betacellulin (BTC), C5a, CCL6, CD48 (SLAMF2), CD6, CD80 (B7-1), Chemerin, Clusterin, Cystatin C, DAN, DLL4, EDAR, Endocan, Fetuin A, H60, IL-33 (IL-1 F11), IL-7 R alpha, Kremen-1, Limitin, Lipocalin-2 (NGAL), LOX-1, Lungkine (CXCL15), Marapsin, Meteorin, Nope, NOV (CCN3), Osteoactivin (GPNMB), OX40 Ligand, P-Cadherin, Periostin, PlGF-2, Progranulin, Prostasin, Renin 1, Testican 3, TIM-1 (KIM-1), TRAIL (TNFSF10), Tryptase epsilon.
Number of Targets Detected:
1
Species Detected:
  • Mouse
Compatible Sample Types:
  • Cell Culture Supernatants
  • Plasma
  • Serum
Design Principle:
  • Sandwich-based
Method of Detection:
Colorimetric
Quantitative/Semi-Quantitative:
Quantitative
Solid Support:
96-well Microplate

Product Specifications

Size:
1, 2, or 5 x 96-Well Strip Microplate Kit

Standard Curves

Spiking & Recovery Results

Linearity Results

Application Notes

Kit Components
  • Pre-Coated 96-well Strip Microplate
  • Wash Buffer
  • Stop Solution
  • Assay Diluent(s)
  • Lyophilized Standard
  • Biotinylated Detection Antibody
  • Streptavidin-Conjugated HRP
  • TMB One-Step Substrate
Other Materials Required
  • Distilled or deionized water
  • Precision pipettes to deliver 2 µl to 1 µl volumes
  • Adjustable 1-25 µl pipettes for reagent preparation
  • 100 µl and 1 liter graduated cylinders
  • Tubes to prepare standard and sample dilutions
  • Absorbent paper
  • Microplate reader capable of measuring absorbance at 450nm
  • Log-log graph paper or computer and software for ELISA data analysis
Protocol Outline
  1. Prepare all reagents, samples and standards as instructed in the manual.
  2. Add 100 µl of standard or sample to each well.
  3. Incubate 2.5 h at RT or O/N at 4°C.
  4. Add 100 µl of prepared biotin antibody to each well.
  5. Incubate 1 h at RT.
  6. Add 100 µl of prepared Streptavidin solution to each well.
  7. Incubate 45 min at RT.
  8. Add 100 µl of TMB One-Step Substrate Reagent to each well.
  9. Incubate 30 min at RT.
  10. Add 50 µl of Stop Solution to each well.
  11. Read at 450 nm immediately.

Storage/Stability

The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.

No posts found

Write A Review

Usage

This product is furnished for LABORATORY RESEARCH USE ONLY.
Not for diagnostic or therapeutic use.

Amazon Gift Card Program