Rabbit Cytokine Array GS3

G-Series Rabbit Cytokine Array 3 Kit. Detects 10 Rabbit Cytokines. Suitable for all liquid sample types.
As low as $252.00
In stock
Only %1 left
Code:
GSL-CYT-3
-
+

Product Description

Specifications

Size 16 Sample Kit, 32 Sample Kit, 64 Sample Kit
Species Rabbit
Number of Targets Detected 10
Quantitative/Semi-Quantitative Semi-Quantitative
Compatible Sample Types Cell Culture Supernatants, Plasma, Serum, Tissue Lysates, Other Body Fluids, Cell Lysates
Solid Support Glass Slide
Method Of Detection Fluorescence Laser Scanner
Design Principle Sandwich-based
More Information Suggested Application

  • Multiplexed Protein Detection
  • Detection of Relative Protein Expression
  • Detecting Patterns of Cytokine Expression
  • Biomarker Screening
  • Identifying Key Factors
  • Confirming a Biological Process
Storage / Stability RayBio® G-Series Arrays are glass slide-based antibody arrays which allow researchers to conduct rapid, accurate expression profiling of hundreds of cytokines, chemokines, growth factors, proteases, soluble receptors and other proteins from any biological fluid. Like a traditional sandwich-based ELISA, this array uses a matched pair of cytokine-specific antibodies for detection. Like the Quantibody® Multiplex ELISA Arrays, G-Series utilizes a highly sensitive and stable fluorescent readout which can be detected by most laser fluorescent scanner systems (see below for more info). After capturing the spot densities with a laser scanner, normalization of the raw data can be easily calculated by the researcher, or by a quick copy-paste into our excel-based Analysis Tool software.

This array as well as all catalog numbers beginning with 'GS' differ from the classic G-Series Arrays in a few important ways. First, each capture antibody is printed in quadruplicate instead of duplicate, delivering higher precision. Secondly, this array features the same antibody panels used in our Quantibody Arrays, allowing a seamless transition to our quantitative multiplex assay platform. Lastly, all 16 wells are spotted as sub-arrays, delivering easy handling of 16 samples simultaneously while consuming low sample volumes (10 - 100 µl per array).
Amazon Gift Cards!

$5 Amazon gift card in every kits purchased.

Introduction

RayBio® G-Series Arrays are glass slide-based antibody arrays which allow researchers to conduct rapid, accurate expression profiling of hundreds of cytokines, chemokines, growth factors, proteases, soluble receptors and other proteins from any biological fluid. Like a traditional sandwich-based ELISA, this array uses a matched pair of cytokine-specific antibodies for detection. Like the Quantibody® Multiplex ELISA Arrays, G-Series utilizes a highly sensitive and stable fluorescent readout which can be detected by most laser fluorescent scanner systems (see below for more info). After capturing the spot densities with a laser scanner, normalization of the raw data can be easily calculated by the researcher, or by a quick copy-paste into our excel-based Analysis Tool software.

This array as well as all catalog numbers beginning with 'GS' differ from the classic G-Series Arrays in a few important ways. First, each capture antibody is printed in quadruplicate instead of duplicate, delivering higher precision. Secondly, this array features the same antibody panels used in our Quantibody Arrays, allowing a seamless transition to our quantitative multiplex assay platform. Lastly, all 16 wells are spotted as sub-arrays, delivering easy handling of 16 samples simultaneously while consuming low sample volumes (10 - 100 µl per array).

Product Features

  • High sensitivity (pg/mL to ng/mL levels)
  • High specificity and system reproducibility
  • Suitable for diverse sample types
  • Low sample volume requirement: 50 µL or less
  • Get results same day (6-hour processing time)
  • Well-suited for high throughput assays
  • Test 16 samples on each slide
  • Data analysis software provides one-step computation

Target Names

Scroll over each target protein for more information

6Ckine
(CCL21)
  • Gene Symbol: CCL21
  • Gene ID: 100144337
  • Accession #: G1TUK2
Angiopoietin-1
ANGPTL3
  • Gene Symbol: ANGPTL3
  • Gene ID: 100358107
  • Accession #: G1SEB2
BLMH
  • Gene Symbol: BLMH
  • Accession #: P13019
Complement MASP3
  • Gene Symbol: masp-1/3
  • Accession #: Q8HYV6
Contactin-1
  • Gene Symbol: CNTN1
  • Gene ID: 100342120
  • Accession #: G1SX46
Matrilin-3
  • Gene Symbol: MATN3
  • Accession #: G1U602
Notch-3
  • Gene Symbol: NOTCH3
  • Accession #: G1U4W4
SREC-II
(SCARF2)
Thrombospondin-2
  • Gene Symbol: THBS2
  • Accession #: G1U1Q1

Application Notes

Suggested Application
  • Multiplexed Protein Detection
  • Detection of Relative Protein Expression
  • Detecting Patterns of Cytokine Expression
  • Biomarker Screening
  • Identifying Key Factors
  • Confirming a Biological Process
Kit Components
  • Antibody Array Slide/s
  • Blocking Buffer
  • Wash Buffer 1
  • Wash Buffer 2
  • Biotinylated Detection Antibody Cocktail
  • Streptavidin-Conjugated Fluor
  • 30 ml Centrifuge Tube
  • Adhesive Plastic Strips
  • Manual
Other Materials Required
  • Distilled or deionized water
  • Small plastic boxes or containers
  • Pipettors, pipette tips and other common lab consumables
  • Orbital shaker or oscillating rocker
  • Aluminum foil
  • Gene microarray scanner or similar laser fluorescence scanner

View Compatible Laser Scanners

Don't have a compatible scanner? RayBiotech now offers FREE scanning service for all RayBio glass slide antibody arrays! Learn More
Protocol Outline
  1. Dry the glass slide
  2. Prepare Standards
  3. Block array surface
  4. Incubate with samples
  5. Incubate with Biotinylated Detection Antibody Cocktail
  6. Incubate with Streptavidin-Conjugated Fluor
  7. Disassemble the glass slide
  8. Scan with a gene microarray laser scanner
  9. Perform densitometry and analysis

Storage/Stability

For best results, store the entire kit frozen at -20°C upon arrival. Stored frozen, the kit will be stable for at least 6 months which is the duration of the product warranty period. Once thawed, store array slide(s), detection antibody cocktail, and Cy3-Conjugated Streptavidin at -20°C and all other reagents undiluted at 4°C for no more than 3 months.