Product Features
- Less sample, more data: up to 24 proteins can be quantified from only 25 µL or less of your precious sample
- 4 hour processing time
- 5-10x more cost-effective than ELISA
- Compatible with most flow cytometers
- No specialized or dedicated instrument(s) needed
- High specificity and system reproducibility
- Well-suited for high throughput assays
Target Names
| APRIL (TNFSF13) |
Fas (Apo-1 antigen / TNFRSF6 / CD95) |
GCSF (CSF3) |
GM-CSF (CSF2) |
ICAM-1 (CD54 / ICAM1) |
| IFN-alpha (IFNA1) |
IFN-beta (IFNB1) |
IFN-gamma (IFNG) |
IL-1 beta (IL-1F2 / IL1B) |
IL-2 (IL2) |
| IL-5 (IL5) |
IL-6 (IL6) |
IL-9 (IL9) |
IL-13 (IL13) |
IL-15 (IL15) |
| IL-17A (IL17A) |
IL-23 alpha (IL-23 p19 / IL23A) |
M-CSF (CSF1) |
SCF (KITLG) |
Siglec-12 (Siglec-E / Siglec-L1 / SIGLEC12) |
| TIMP-4 (TIMP4) |
TNF alpha (TNFA) |
TRAIL (TNFSF10) |
VEGFA |
|
Kit Components
- RayPlex® Magnetic Multiplex Bead Cocktail
- Assay Diluent
- Wash Buffer
- RayBio® Serum/Plasma Diluent
- Lyophilized Protein Standard Mix
- Biotinylated Detection Antibody Cocktail
- PE Conjugate
- Flow Cytometer Setup Bead Cocktail
- V-bottom 96-well Microplate
- Flat-bottom 96-well Microplate
Additional Materials Required
- Orbital 96-well plate shaker (with ability to reach 1000 rpm)
- Flow Cytometer with blue (or green) and red lasers capable of measuring phycoerythrin (PE), Alexa Fluor 700 (AF700), and Alexa Fluor 647 (AF647)/APC channels OR Luminex instrument
- Aluminum foil or 96-well Plate Aluminum Sealers
- PBS
- Deionized (DI) water
- 1.5 mL polypropylene microcentrifuge tubes or similar
- Microcentrifuge
- Recommended: Automated plate washing system with magnetic separation
- Optional: 96-well round bottom plate (to prepare samples)
- Optional: High throughput sampler (HTS) for 96-well plate reading
- Optional: Vacuum manifold compatible with a 96-well microplate if using a Filter 96-Well Microplate
Don't have a compatible flow cytometer? RayBiotech provides full testing services for RayPlex™ bead arrays. Get a quote!
Assay Procedure Summary
- Prepare Reagents, Standards, and Samples
- Add RayPlex® Magnetic Multiplex Bead Cocktail to each well
- Incubate with Samples and Standards
- Incubate with Biotinylated Detection Antibody Cocktail
- Incubate with PE Conjugate
- Analyze with a compatible flow cytometer
- Perform data analysis
Storage/Stability
Upon receipt, the Lyophilized Protein Standard Mix should be stored at -20°C or below. Other components should be stored at 4°C. Use reagents immediately after preparation. If stored at the proper temperature, the kit will retain complete activity for at least 6 months.