Product Features
- Less sample, more data: up to 19 proteins can be quantified from only 25 µL or less of your precious sample
- 4 hour processing time
- 5-10x more cost-effective than ELISA
- Compatible with most flow cytometers
- No specialized or dedicated instrument(s) needed
- High specificity and system reproducibility
- Well-suited for high throughput assays
Target Names
| CCL1 (I-309) |
CCL2 (MCP-1) |
CCL3 (MIP-1α) |
CCL4 (MIP-1β) |
CCL5 (RANTES) |
| CCL7 (MCP-3) |
CCL17 (TARC) |
CCL19 (MIP-3β, ELC, CK beta 11) |
CCL20 (MIP-3α) |
CCL22 (MDC) |
| CCL24 (Eotaxin-2) |
CCL27 (CTACK, ILC, PESKY, ESKINE) |
CX3CL1 (Fractalkine) |
CXCL1 (KC) |
CXCL2 (MIP-2α) |
| CXCL12 (SDF-1α) |
CXCL13 (BLC) |
CXCL16 (SR-PSOX) |
CXCL17 (DMC, VCC-1) |
|
Kit Components
- RayPlex® Magnetic Multiplex Bead Cocktail
- Assay Diluent
- Wash Buffer
- RayBio® Serum/Plasma Diluent
- Lyophilized Protein Standard Mix
- Biotinylated Detection Antibody Cocktail
- PE Conjugate
- Flow Cytometer Setup Bead Cocktail
- V-bottom 96-well Microplate
- Flat-bottom 96-well Microplate
Additional Materials Required
- Orbital 96-well plate shaker (with ability to reach 1000 rpm)
- Flow Cytometer with blue (or green) and red lasers capable of measuring phycoerythrin (PE), Alexa Fluor 700 (AF700), and Alexa Fluor 647 (AF647)/APC channels OR Luminex instrument
- Aluminum foil or 96-well Plate Aluminum Sealers
- PBS
- Deionized (DI) water
- 1.5 mL polypropylene microcentrifuge tubes or similar
- Microcentrifuge
- Recommended: Automated plate washing system with magnetic separation
- Optional: 96-well round bottom plate (to prepare samples)
- Optional: High throughput sampler (HTS) for 96-well plate reading
- Optional: Vacuum manifold compatible with a 96-well microplate if using a Filter 96-Well Microplate
Don't have a compatible flow cytometer? RayBiotech provides full testing services for RayPlex™ bead arrays. Get a quote!
Assay Procedure Summary
- Prepare Reagents, Standards, and Samples
- Add RayPlex® Magnetic Multiplex Bead Cocktail to each well
- Incubate with Samples and Standards
- Incubate with Biotinylated Detection Antibody Cocktail
- Incubate with PE Conjugate
- Analyze with a compatible flow cytometer
- Perform data analysis
Storage/Stability
Upon receipt, the Lyophilized Protein Standard Mix should be stored at -20°C or below. Other components should be stored at 4°C. Use reagents immediately after preparation. If stored at the proper temperature, the kit will retain complete activity for at least 6 months.