RayBio® Estradiol Enzyme Immunoassay Kit is a competitive enzyme immunoassay developed for rapid E2 detection within 2.5 hours in serum and plasma samples collected from various species.
| Size | 1 Plate Kit, 2 Plate Kit, 5 Plate Kit |
| Estimated Lead Time | 1-2 business days |
| Species | Human, Rabbit, Ovine (Sheep), Canine (Dog), Equine (Horse), Feline (Cat), Porcine (Pig) |
| Sensitivity | 0.09 pg/ml |
| Detection Range | 0.01 pg/ml - 10,000 pg/ml |
| Compatible Sample Types | Plasma, Serum, Urine |
| Recommended Dilution (Serum/Plasma) | 2-3 folds |
| Quantitative/Semi-Quantitative | Quantitative |
| Solid Support | 96-well Microplate |
| Design Principle | Competition-based |
| Method Of Detection | Colorimetric |
| Shipping Type | Blue ice |
| Storage | -20°C |
The entire kit may be stored at -20°C to -80°C for up to 1 year from the date of shipment. For extended storage, it is recommended to store it at -80°C. Avoid repeated freeze-thaw cycles.
RayBio® Estradiol Enzyme Immunoassay Kit is a competitive enzyme immunoassay developed for rapid E2 detection within 2.5 hours in serum and plasma samples collected from various species.
Estradiol ELISA Kit
Estradiol ELISA Kit
We used this kit to measure estradiol in serum samples across multiple 96-well plates. Although the assay protocol was straightforward to follow, we experienced substantial issues with standard-curve performance. Across multiple independently prepared plates, several of the mid-to-upper standards produced unexpected OD patterns, including little change between successive concentrations and, in some instances, changes in the opposite direction from what would be expected for the assay. Because similar behavior occurred across plates prepared on separate days, we had concerns regarding the reliability of quantitative interpolation. One plate produced a substantially better standard curve, although a number of sample values on that plate were also unexpectedly low. Based on our experience, I would recommend carefully evaluating the full standard curve and QC performance before interpreting sample concentrations from this assay.
Review by Academic Researcher, from University Research Laboratory, on Sep 17, 2026
I used this kit to check for the absorption of estradiol into PDMS and this kit was very useful. I discovered results that no one expected and the consistency of the kit insured that my data were robust and accurate. The instructions were clear and the kit contents ample. I will continue using Raybiotech's products. Their customer service is also exceptional.
Review by Dylan Gordon, from CFD Research Corporation, on Dec 19, 2025